Krag Collectors Association Forum Archive
General >> Ammunition, reloading, shooting, etc >> 30-40 Krag case necks are splitting
http://www.kragcollectorsassociation.org/cgi-bin/yabb2/YaBB.pl?num=1494129785

Message started by Rebel-Yell on May 7th, 2017 at 4:03am

Title: Re: 30-40 Krag case necks are splitting
Post by Parashooter on May 8th, 2017 at 11:53pm
The real question here is - why are these cases failing on first or second firing? Possibilities include:
    Dodgy metallurgy.
    Scratched/burred drawing dies/punches
    Storage conditions (corrosion?)
    Inadequate anneal during manufacture.
    Oversize/rough chamber.

Annealing before further firing can address only some of these issues.